There are no items in the shopping cart.
Condition:[NEW - Manufacturer Packed]
Brand:SCHNEIDER ELECTRIC
Model:LV432694
Code:LV432694SCH
Weight:1.000 KG
MOQ:0
Number of Poles :4P
Current Rating:400A

More parameters>>

Quantity
On Hand    Group Stock    ETA Delivery   
Shipping time may vary.
VitalMRO rep will advise.


 ~ 

Product Filter

Clear All

Number of Poles
Current Rating
Range
Coil Voltage (AC)
Contact Voltage Rating
Breaking Capacity
  • Product
  • Attribute
  • Price
  • Add To Cart
  • Products Detail
  • Specification parameter
  • Products Q&A
Mobile phone purchase
goods qr code
Add To Cart
Price:
Quantity:
Inventory  PcsAccount Inventory  Pcs

Products Detail

Replacement Suggest:


VitalMRO is Authorized Distributor for This Product. 


Main
rangeComPact
product nameComPact NSX
range of productComPact NSX400...630
device short nameNSX400N
product or component typeCircuit breaker
device applicationDistribution
Number of poles4P
protected poles description3t + N/2
3t
4t
neutral positionLeft
[In] rated current400 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
network typeAC
network frequency50/60 Hz
suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA at 240 V AC 50/60 Hz conforming to UL 508
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
50 kA at 480 V AC 50/60 Hz conforming to UL 508
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelN 50 kA 415 V AC
trip unit nameMicrologic 2.3
trip unit technologyElectronic
trip unit protection functionsLSoI
control typeToggle
Circuit breaker mounting modeFixed

Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
mechanical durability15000 cycles
electrical durability3000 cycles at 690 V In
6000 cycles at 690 V In/2
6000 cycles at 440 V In
12000 cycles at 440 V In/2
mounting supportBackplate
upside connectionFront
downside connectionFront
connection pitch45 mm
protection typeL : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
trip unit rating400 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range160...400 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range16 s at 6 x Ir
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5...10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range4800 A
earth-leakage protectionWithout
Neutral protection settings0.5 x Ir (3t + N/2)
1 x Ir (4t)
No protection (3t)
zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries6 slot(s)
local signallingFlashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W)185 mm
Height (H)255 mm
Depth (D)110 mm
net weight7.9 kg
Environment
standardsEN/IEC 60947
product certificationsCCC
EAC
Marine
overvoltage categoryClass II
electrical shock protection classClass II
pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
ambient air temperature for storage-50…85 °C
relative humidity0…95 %
operating altitude0...2000 m without derating
2000 m...5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.082 cm
Package 1 Width20.207 cm
Package 1 Length29.155 cm
Package 1 Weight7.314 kg
Unit Type of Package 2S04
Number of Units in Package 23
Package 2 Height30.0 cm
Package 2 Width40.0 cm
Package 2 Length60.0 cm
Package 2 Weight22.852 kg



100 Rate %
I haven't set up the buyer's impression yet. Please wait with me~
No comment

User discussion circle

Subscribe to get more info
Compare

1

You can also continue adding

2

You can also continue adding

3

You can also continue adding

4

You can also continue adding